8m³ Walk In High Low Temperature Humidity Environmental Test Chamber

  • 1
  • 2
  • 3

Brand Name : Sinuo

Model Number : SN886-8m³

Certification : Calibration Certificate (Cost Additional)

Place of Origin : China

MOQ : 1

Payment Terms : T/T

Delivery Time : 45 days

Price : Customized

Supply Ability : 10 sets/month

Packaging Details : Plywood Case

Applied Standard : IEC60068 series

Effective Volume : 8m³

Temperature Range : -60°~ 120℃

Temperature Uniformity : ±2℃

Humidity Range : 30%RH~98%RH

Humidity Deviation : ±5.0%RH

Heating Rate : ≤2.5°C/min

Cooling Rate : Average 1.0 ° C / min

Contact Now

8m³ Walk In High Low Temperature Humidity Environmental Test Chamber

Complied Standards & Clauses


IEC60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”

IEC60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”

IEC60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle) , IDT”

IEC60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”

Equipment Overview


Applications: It is used for high and low temperature and damp heat tests on electricians, electronics, machinery, and large parts, semi-finished products, and finished products. Process quality and reliability testing of products, parts, etc. under simulated temperature and humidity conditions.

Test Principle: The heating, humidification and refrigeration system is used to control and change the ambient temperature and humidity in the chamber, simulating the ambient temperature / humidity and alternating procedures required by the testing.

Structure: Adopts closed chamber structure.

Technical Parameters


Control & Operation PLC and touch screen intelligent control system
Chamber Size (Optional)

8m3: WDH=2×2×2m

Temperature Range (Optional)

Maximum test temperature: 80 ° C, 120 ° C;

Minimum test temperature: -60 ° C, -40 ° C, -20 ° C, 0 ° C

Temperature Deviation ≦±2.0℃
Temperature Fluctuation ±0.5℃
Temperature Uniformity ±2℃
Humidity Range 30%〜98%RH
Humidity Deviation ±5.0%RH
Heating Rate ≤2.5°C/min (nonlinear, no load)
Cooling Rate Average 1.0 ° C / min
Temperature and Humidity Range Icon 8m³ Walk In High Low Temperature Humidity Environmental Test Chamber
System Main Composition
Chamber Body The inner chamber is made of SUS304# stainless steel plate, rounded shape, smooth, easy for clean
The outer chamber is made of A3 cold-rolled steel plate electrostatic double-sided spray or SUS304 stainless steel
Lead hole: inner and outer chambers are equipped with a threading hole with a rubber stopper
Insulation material: polyurethane foam
Observation window: double-layer explosion-proof tempered glass door
Heating System Heating method: electric heating
High quality nickel-chromium wire electric heater, contactless control (SSR)
Humidification System Humidification method: external humidification structure
Cooling System German Bock semi-tight compressor or German BITZER semi-compact compressor
Non-fluorine environmentally friendly refrigerant R404A R23, in line with environmental regulations, safe and non-toxic.
Shell and tube condenser (water cooled).
High-performance fin type automatic load capacity adjustment, long-term use of low temperature and high humidity conditions without frosting.
Control System Touch screen: Weinview programmable temperature and humidity controller (7 inch 16-bit true color touch screen)
Temperature control: PID self-tuning, using Class A PT100 platinum resistance sensor

Function: fixed value test and program test

Fixed value test: When the test environment requires only a single temperature and humidity, selecting this mode to set the required temperature, humidity and running time.

Program test: When the test environment requires multiple temperatures and humidity, select this mode to set the temperature, humidity and running time of each program. User can set the program running sequence. The program group is up to 100 groups.

Data Storage With temperature and humidity curve interface, with standard R232 interface or U disk communication interface, the data can be downloaded, and the data changes and processes can be recorded.
Safety Protection Power-off memory function, phase sequence protection, leakage protection, over-temperature protection, compressor overload protection, water shortage alarm, abnormal protection
Safety Protection Device Heater air-burning protection switch, heater over current circuit breaker, circulating fan over current overload protection
Compressor high voltage protection switch, compressor overheat protection switch, compressor over current protection switch
Under-reverse phase circuit breaker, no-fuse switch, zero-crossing gate fluid power controller
Alarm Indication When the above protection occurs, the equipment stops running, an audible and visual alarm is issued, and the fault location is displayed on the meter.


Product Tags:

PLC control Walk In Environmental Test Chamber

      

8m3 Walk In Environmental Test Chamber

      

PLC control constant temperature humidity chamber

      
Buy cheap 8m³ Walk In High Low Temperature Humidity Environmental Test Chamber product

8m³ Walk In High Low Temperature Humidity Environmental Test Chamber Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Sinuo Testing Equipment Co. , Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0